聚氯乙烯绝缘硬线的技术数据
聚氯乙烯绝缘硬线的技术数据 | |||||||
型号 | 额定电压 U0/U(V) | 芯数 | 标称截面 (mm2) | 线芯根数/直径 (mm) | 最大外径 (mm) | 单位质量 (kg/km) | |
BV | 300/500 | 1 | 0.5 0.75 0.15 1.0 1.0 | 1/0.80 1/0.97 7/0.37 1/1.13 7/0.43 | 2.4 2.6 2.8 2.8 3.0 | 8.5 11.1 12.0 13.9 15.0 | |
450/750 | 1 | 1.5 1.5 2.5 2.5 4 4 6 6 10 16 25 35 50 70 95 120 150 185 240 300 400 | 1/1.38 7/0.52 1/1.78 7/0.68 1/2.25 7/0.85 1/2.76 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 | 3.3 3.5 3.9 4.2 4.4 4.8 4.9 5.4 7.0 8.0 10.0 11.5 13.0 15.0 17.5 19.0 21.0 23.5 26.5 29.5 33.0 | 20.3 21.6 31.6 34.8 47.1 50.3 67.1 71.2 119 179 281 381 521 734 962 1180 1470 1810 2350 2930 3870 | ||
BLV | 450/750 | 1 | 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 | 1/1.78 1/2.25 1/2.76 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 | 3.9 4.4 4.9 7.0 8.0 10.0 11.5 13.0 15.0 17.5 19.0 21.0 23.5 26.5 29.5 33.0 | 17 22 29 62 78 118 156 215 282 385 431 539 666 857 1070 1390 | |
BVR | 450/750 | 1 | 2.5 4 6 10 16 25 35 50 70 | 19/0.41 19/0.52 19/0.64 49/0.52 49/0.64 98/0.58 133/0.58 133/0.68 189/0.68 | 4.2 4.8 5.6 7.6 8.8 11.0 12.5 14.5 16.5 | 34.7 51.4 73.6 129 186 306 403 553 764 | |
型号 | 额定电压 U0/U(V) | 芯数 | 标称截面 (mm2) | 线芯根数/直径 (mm) | 外径(mm) | 单位质量 (kg/km) | |
下限 | 上限 | ||||||
BVV | 300/500 | 1 | 0.75 1.0 1.5 1.5 2.5 2.5 4 4 6 6 10 | 1/0.97 1/1.13 1/1.38 7/0.52 1/1.78 7/0.68 1/2.25 7/0.85 1/2.76 7/1.04 7/1.35 | 3.6 3.8 4.2 4.3 4.8 4.9 5.4 5.4 5.8 6.0 7.2 | 4.3 4.5 4.9 5.2 5.8 6.0 6.4 6.8 7.0 7.4 8.8 | 23 26.4 34.6 36.5 46.4 51.5 65.9 73.3 91.6 97.6 152.0 |
2 | 1.5 1.5 2.5 2.5 4 4 6 6 10 | 1/1.38 7/0.52 1/1.78 7/0.68 1/2.25 7/0.85 1/2.76 7/1.04 7/1.35 | 8.4 8.6 9.6 9.8 10.5 10.5 11.5 11.5 15.0 | 9.8 10.5 11.5 12.0 12.5 13.0 13.5 14.5 18.0 | 109 123 157 172 205 222 265 286 471 | ||
3 | 1.5 1.5 2.5 2.5 4 4 6 6 10 | 1/1.38 7/0.52 1/1.78 7/0.68 1/2.25 7/0.85 1/2.76 7/1.04 7/1.35 | 8.8 9.0 10.0 10.0 11.0 11.0 12.5 12.5 15.5 | 10.5 11.0 12.0 12.5 13.0 14.0 14.5 15.5 19.0 | 136 146 190 207 252 272 344 369 574 | ||
4 | 1.5 1.5 2.5 2.5 4 4 6 6 | 1/1.38 7/0.52 1/1.78 7/0.68 1/2.25 7/0.85 1/2.76 7/1.04 | 9.6 9.6 11.0 11.0 12.5 12.5 14.0 14.0 | 11.5 12.0 13.0 13.5 14.5 15.5 16.0 17.5 | 164 174 228 252 321 346 439 470 | ||
5 | 1.5 1.5 2.5 2.5 4 4 6 6 | 1/1.38 7/0.52 1/1.78 7/0.68 1/2.25 7/0.85 1/2.76 7/1.04 | 10.0 10.5 11.5 12.0 13.5 14.0 15.0 15.5 | 12.0 12.5 14.0 14.5 16.0 17.0 17.5 18.5 | 192 205 272 292 379 418 518 550 | ||
BLVV | 300/500 | 1 | 2.5 4 6 10 | 1/1.78 1/2.25 1/2.76 7/1.35 | 4.8 5.4 5.8 7.2 | 5.8 6.4 7.0 8.8 | 31.1 41.0 50.6 81.1 |
BV-105 | 450/750 | 1 | 0.5 0.75 1.0 1.5 2.5 4 6 | 1/0.80 1/0.97 1/1.13 1/1.38 1/1.78 1/2.25 1/2.76 |
| 2.7 2.8 3.0 3.3 3.9 4.4 4.9 | 9.5 12.2 15.1 20.3 32.0 47.1 67.1 |
BVVB | 300/500 | 2 | 0.75 1.0 1.5 2.5 4 6 10 | 1/0.97 1/1.13 1/1.38 1/1.78 7/0.85 7/1.04 7/1.35 | 3.8×5.8 4.0×6.2 4.4×7.0 5.2×8.4 5.6×9.6 6.4×10.5 7.8×13.0 | 4.6×7.0 4.8×7.4 5.4×8.4 6.2×9.8 7.2×11.5 8.0×13.0 9.6×16.0 | 43.7 51.9 65.9 95.7 146.0 200.0 323.0 |
3 | 0.75 1.0 1.5 2.5 4 6 10 | 1/0.97 1/1.13 1/1.38 1/1.78 7/0.85 7/1.04 7/1.35 | 3.8×8.0 4.0×8.4 4.4×9.8 5.2×11.5 5.8×13.5 6.4×15.0 7.8×19.0 | 4.6×9.4 4.8×9.8 5.4×11.5 6.2×13.5 7.4×16.5 8.0×18.0 9.6×22.5 | 62.6 74.3 95.6 140 220 295 485 | ||
BLVVB | 300/500 | 2 | 2.5 4 6 10 | 1/1.78 1/2.25 1/2.76 1/1.35 | 5.2×8.4 5.6×9.4 6.2×10.5 7.8×13.0 | 6.2×9.8 6.8×11.0 7.4×12.0 9.6×16.0 | 64.9 80.7 104 177 |
3 | 2.5 4 6 10 | 1/1.78 1/2.25 1/2.76 7/1.35 | 5.2×11.5 5.8×13.0 6.2×14.5 7.8×19.0 | 6.2×13.5 7.0×15.0 7.4×17.0 9.6×22.5 | 93.9 123 153 261 | ||